Updated Nov 18, 2026· 7 min read

Key takeaways

  • Portable diesel generators — wheeled or skid-mounted units with an onboard fuel tank, commonly used on job sites, for RV/camping backup, or as temporary power during an outage. These need manual fuel storage and refueling but don’t depend on any utility connection.
  • Standby natural gas generators — permanently installed units wired into a home’s electrical panel and plumbed into an existing gas line, usually paired with an automatic transfer switch that starts the generator within seconds of a utility outage. These need professional installation but run with minimal owner intervention.
  • Bi-fuel or dual-fuel generators — units that can run on diesel plus natural gas (or propane), giving flexibility to use whichever fuel is available or to extend runtime by supplementing diesel with gas. These are more common in commercial and industrial settings than residential ones.

Choosing between diesel and natural gas generators comes down mostly to fuel access and run pattern: diesel suits sites without a gas line that need to store fuel on-site for extended outages, while natural gas suits properties already connected to a gas utility line that want a generator that never needs refueling during a storm. Portable diesel units suit job sites and backup power away from utility lines; standby natural gas generators tied into a home’s existing gas line suit homeowners who want automatic backup power without maintaining a fuel tank.

Diesel generators store their fuel in an onboard tank, which means total runtime is capped by tank size and needs manual refueling for extended outages, but that stored fuel is available immediately without depending on an external utility. Natural gas generators tap into a home or facility’s existing gas line (or a propane tank for bi-fuel/LP-capable models), which means essentially unlimited runtime as long as the gas supply holds, but during a natural disaster that also disrupts gas service, that supply isn’t guaranteed. Diesel engines also tend to be more fuel-efficient per hour of operation and more durable for prolonged heavy-load use, which is why diesel remains common for job-site and industrial backup power, while natural gas standby units are more common for home backup because of the no-refueling convenience.

Types of Diesel and Natural Gas Generators

  • Portable diesel generators — wheeled or skid-mounted units with an onboard fuel tank, commonly used on job sites, for RV/camping backup, or as temporary power during an outage. These need manual fuel storage and refueling but don’t depend on any utility connection.
  • Standby natural gas generators — permanently installed units wired into a home’s electrical panel and plumbed into an existing gas line, usually paired with an automatic transfer switch that starts the generator within seconds of a utility outage. These need professional installation but run with minimal owner intervention.
  • Bi-fuel or dual-fuel generators — units that can run on diesel plus natural gas (or propane), giving flexibility to use whichever fuel is available or to extend runtime by supplementing diesel with gas. These are more common in commercial and industrial settings than residential ones.

What to Look For

Power output (running vs. starting watts)

Running watts (continuous output) needs to cover everything that will be powered at once, while starting watts (a brief surge) needs to cover the highest single-item surge, which is often an air conditioner or well pump compressor kicking on. Makers list both figures, and sizing a generator against a home or site’s actual load list, rather than just a general size category, avoids an underpowered unit.

Runtime and fuel source reliability

Diesel units’ runtime is tied to onboard tank size and the generator’s fuel consumption rate at a given load, both of which the maker states; a bigger tank means longer unattended runtime but also a heavier, bulkier unit. Natural gas standby units avoid tank-size limits entirely but depend on the gas utility staying operational, which is worth considering for anyone in an area prone to disasters that can disrupt gas lines along with power.

Noise level and placement

Standby natural gas units are typically installed outdoors on a pad at a set distance from the home per local code and the maker’s manual, and their stated decibel rating matters for anyone with close neighbors. Portable diesel units need safe, ventilated placement outdoors, well away from windows and doors, because of exhaust fumes.

Maintenance requirements

Diesel engines generally need regular fuel filter changes, periodic fuel stabilization or rotation if stored long-term, and more involved maintenance than a comparable gas unit; makers’ manuals lay out specific service intervals. Natural gas standby generators typically run a scheduled self-test automatically and need less manual fuel maintenance, though both types need regular oil changes per the manual.

At a Glance

Format Best For Key Stated Specs Limits
Portable diesel generator Job sites, off-grid backup, locations without gas service Onboard fuel tank, running/starting watt ratings, wheeled or skid-mount Needs manual refueling for extended runs; fuel storage and rotation required
Standby natural gas generator Homes with an existing gas line wanting automatic backup Automatic transfer switch, runs on utility gas line, continuous runtime while gas supply holds Depends on gas utility staying active; needs professional installation
Bi-fuel/dual-fuel generator Commercial/industrial sites wanting fuel flexibility Can run on diesel plus natural gas or propane More complex and costly than single-fuel units; less common for home use

Pick X If…

If you… Choose
Don’t have a gas utility line at your property A portable diesel generator
Already have gas service and want hands-off automatic backup A standby natural gas generator with auto transfer switch
Need backup power on a job site with no utility access A portable diesel generator sized to your tool/equipment load
Run critical operations that can’t risk losing gas supply A bi-fuel generator or a diesel unit with on-site fuel storage

Fit and Compatibility Notes

Standby natural gas generators need to be sized against the gas meter and line’s maximum delivery capacity, not just the generator’s own rated draw, since an undersized gas line can starve the generator under full load; a licensed gas contractor typically checks this during installation. Diesel generators need adequate ventilated storage for fuel if runtime beyond the onboard tank is expected, and stored diesel fuel can degrade over time without a stabilizer, so anyone planning to keep a generator fueled and ready for occasional emergency use should follow the maker’s fuel storage guidance. Electrical connection to a home’s panel, for either fuel type when used for whole-home backup, should go through a properly installed transfer switch rather than any makeshift connection, both for safety and to avoid back-feeding power into utility lines.

A Few Alternatives Worth Knowing About

Gasoline-powered portable generators remain the most common and generally least expensive option for occasional, short-duration backup power, though gasoline has a shorter safe storage life than diesel and is more flammable to store in quantity. Propane-fueled generators offer some of the same no-refueling-during-use convenience as natural gas while not requiring a utility gas line, using a refillable propane tank instead, which makes them a middle option for properties without gas service. Battery-based home backup systems paired with solar panels are a fuel-free alternative gaining attention for quieter, emissions-free backup, though their stored capacity and output are generally smaller than a comparably priced fuel generator’s continuous output.

Safety Notes

Any generator producing carbon monoxide should never run indoors or in an attached garage, even with doors open, and a home with a standby or frequently used portable generator should have working carbon monoxide detectors per safety guidance. Installation of a standby generator and its transfer switch should be done by a licensed electrician and, for the gas connection, a licensed gas contractor, following local code. Diesel fuel storage, generator placement, and exhaust clearance should all follow the manufacturer’s manual and local fire code rather than general assumptions.

Frequently Asked Questions

Is a natural gas generator cheaper to run than a diesel generator?

Running cost depends on local fuel and utility gas pricing, which varies by region and over time, so neither fuel type is universally cheaper. Diesel engines are generally more fuel-efficient per hour of output, which can offset a higher per-unit diesel price depending on local rates.

What happens to a natural gas generator if the gas utility goes down?

A natural gas generator depends entirely on its gas supply, so if the utility line itself is disrupted, such as during certain natural disasters, the generator will not run regardless of the electrical outage. This is the main reason some buyers in disaster-prone areas choose diesel or propane with on-site fuel storage instead.

How big a generator do I need for my home or job site?

Sizing depends on the total running watts of everything that needs power at once plus the starting watts of the largest single surge load, both of which the equipment manufacturers and generator maker list. A licensed electrician or the generator manufacturer’s sizing guidance can help match a specific model to an actual load list rather than guessing.

Do I need a permit to install a standby generator?

Most jurisdictions require a permit for a permanently installed standby generator because it involves both electrical and gas connections, and requirements vary by location. Checking with the local building department before installation avoids issues with inspections or future home sales.

How often does a diesel generator need maintenance compared to natural gas?

Diesel generators generally need more frequent attention to fuel filters, fuel quality, and periodic exercise runs, especially if fuel sits unused for long periods between outages. Natural gas standby units typically run brief automatic self-tests on a schedule and need less direct fuel-related maintenance, though both types need regular oil changes per the manufacturer’s manual.

Can a generator be converted from diesel to natural gas or vice versa?

Some generators are designed as dedicated single-fuel units and are not intended for conversion, while bi-fuel or dual-fuel models are built from the factory to run on more than one fuel type. Converting a single-fuel generator after purchase is generally not supported by the manufacturer and can void the warranty, so checking a bi-fuel model’s specifications before purchase is the more reliable path to fuel flexibility.

A